8.4 Application Examples
8-4
8.4
Application Examples
8.4.1
Turning ON Only the Servo Power Supply for the
Selected Control Group at Teaching
At turning the servo ON, only the servo power supply for the selected control group can be
turned ON.
As shown below, when the servo power supply is turned ON with only the “ON_EN” signal of
contactor unit connected to R1 set to “ON,” the servo power is supplied only to R1.
8.4.2
Turning OFF Only the Servo Power Supply for the
Selected Control Group at Playback
When an operator touches the positioner in such a case as replacement of workpiece, only
the servo power supply for the positioner to be touched can be turned OFF for security.
R1
R2
S1
S2
S3
S4
EDIT
DISPLAY
UTILITY
DATA
Short Cut
Main Menu
SERVO POWER STATUS
ON-EN SIGNAL SERVO ON
Workpiece replacing work
(Servo power OFF)
NX100
S1
R1
S2
During operation
(Servo power ON)
Contactor
unit #2
Contactor
unit #1
Contactor
unit #3
194/210