7
Disassembly and Reassembly of the Speed Reducers
7.2
Disassembly and Reassembly of L-Axis Speed Reducer
7-6
HW1485471
HW1485471
Reassembly
1. Mount the O-ring
on the speed reducer
.
2. Apply ThreeBond 1206C to the contact surface of the S-head and the
speed reducer
. For the place to apply sealing bond, refer to “S-
head side” in
fig. 7-2(b) “Surface to Apply Sealing Bond on the L-Axis
3. Mount the speed reducer
on the S-head, and then tighten the
hexagon socket head cap screws
with the tightening torque shown
table 7-2 “L-Axis Speed Reducer Parts Checklist”
4. Apply ThreeBond 1206C to the contact surface of the speed reducer
and the L-arm
.
For the place to apply sealing bond, refer to “L-arm side” in
5. Mount the L-arm
on the speed reducer
. Tighten the hexagon
socket head cap screws
with the tightening torque shown in
6. Assemble the L-axis motor
, and mount the L-axis motor on the S-
chapter 6.2 “Disassembly and Reassembly of the L-
.)
(When replacing the speed reducer, replace the input gear
, too.)
7. Mount the balancer. (Refer to
8. Remove the hexagon socket head plugs from the grease inlet and the
grease exhaust port, and then replenish grease (Molywhite RE No.00)
from the grease inlet.
Tighten the hexagon socket head plugs on the grease inlet and the
grease exhaust port after the replenishment of grease. (Refer to
chapter 5.1.2 “Grease Exchange Procedure”
(L-axis).)
9. Turn ON the power supply of the YRC1000.
NOTE
For removing/applying of sealing bond and assembling after
applying sealing bond, refer to
Applying, Assembling of Sealing Bond”
NOTE
If grease is filled before the sealing bond is solidified, it may
cause grease to leak.
After tightening the screws, leave it 30 minutes or more, and
then fill with grease.
3
1
1
1
4
1
5
5
1
2
6
7
69/134