9-5
175873-1CD
HW1483557
9
Maintenance and Inspection
9.2 Battery Pack Replacement
VS100
9.2
Battery Pack Replacement
The battery packs (type: HW0470360-A) are installed in the position
shown in
. If a battery alarm occurs in the
DX200, replace the battery in accordance with the following procedures:
Fig. 9-2: Battery Location
Fig. 9-3: Battery Connection
Battery pack
(HW0470360-A)
Plate
(b) Top View
(a) Back View
6
'&3:
)%7
'1(7
%&
%&
$,5
*UHDVH
0RO\:KLWH
5(1R
,1
Cross head APS bolt M4
(length: 10mm) (4 bolts)
(For cover plate fixing)
Cross head APS bolt M6
(length: 12mm) (8 bolts)
Connector base
Connector
Circuit board
See step 5 below
Battery pack before replacement
See step 4 below
(Type: SGDR-EFBA02A)
New battery pack
57 of 91