7
System Application
7.2 Internal User I/O Wiring Harness and Air Lines for User’s System
Applications
7-3
175873-1CD
HW1483557
VS100
Fig. 7-2: Connectors for Internal User I/O Wiring Harness and Air Lines for
User’s Applications
A
B
Tube for the field bus cable (inside dia. 12 mm)
(in the base)
AIR
1BC
2BC
D-NET
)%7
FBT
AIR
DC-PW
S1
Cover for the field bus
Pan-head sems screw M3 (length:6) (4 places )
The tube (inside dia. 12 mm) is equipped in the base.
27
27
Connector for +24V CM03A-R4P-S-1
Prepare pin connector CM03-P4S
Connector for the internal I/O wiring harness:
JL05-2A24-28PC (with a cap)
Prepare pin connector JL05-6A24-28S
Cable for the primary source for welding
22mm
2
×2 cables
1.25mm
2
×3 cables
14mm
2
×1 cable
Terminal-A 1.25-3
Terminal-A R22-8
Terminal-A R14-8
Connector for the D-NET CM02-8DR5P-CF
Prepare pin connector CM02A-8DP5S-D
View B
Rc 1/2 Tap
Cooling water 4
Rc 1/2 Tap
Cooling water 2
Rc 1/2 Tap
Cooling water 1
Rc 1/2 Tap
Cooling water 3
Rc 3/8 Tap
Air
Cooling water 4
Rc 3/8 Tap
Connector for the external axis encoder cable:
JL05-2A20-29SC(socket connector with a cap)
Prepare pin connector JL05-6A20-29P
Connector for +24V 1R4030
Prepare pin connector
CM03-J4P
Connector for the D-NET 8R5L30
Prepare pin connector 8A5006-32DN
Connector for the internal I/O wiring harness
(the casing side):
JL05-2A24-28SC (with a cap)
Prepare pin connector JL05-6A24-28P
Connector for the primary source for welding
MS3100A36-3S (with a cap)
Prepare pin connector MS3106B36-3P
Connector for the external axis power cable:
JL05-2A18-1SC-F0 (with a cap)
Prepare pin connector JL05-6A18-1P
Rc 3/8 Tap
Rc 3/8 Tap
Cooling water 1
Cooling water 2
Rc 3/8 Tap
Rc 3/8 Tap
Cooling water 3
Air
View A
46 of 91