4.4 List of Common Parameters
4-20
HW0480311
HW0480311
C18
Current calibration reference
current 2 (File 3)
250
A
Reference current 2 for the user
file No.3
C19
Reserved for system
0
Do not change.
C20
Reserved for system
0
Do not change.
C21
Reserved for system
41
Do not change.
C22
Reserved for system
0
Do not change.
C23
System Reset
0
When the C parameter C23 is set
to "2004", System Reset is exe-
cuted to initialize all parameters
(default setting).
Before executing System Reset,
record the modified parameters.
After executing System Reset, turn
OFF the welding source and turn
ON again.
When the power supply is turned
OFF, the C parameter C23 is back
to "0".
C24
Reserved for system
0
Do not change.
C25
Motor current warning value
70
% (for
motor
rated
current
)
The value at which the warning is
output for the excess current of
feeding motor
C26
Reserved for system
48
Do not change.
C27
Reserved for system
600
Do not change.
C28
Error: outside the range of out-
put current
0
0: If the output current is outside
the range, the error (Err790,
Err791) is issued after welding.
1: If the output current is outside
the range, the error (Err790,
Err791) is issued during welding
and the welding stops.
2: If the output current is outside
the range, the error is not
issued.
C29
Setting range of the error: out-
side the range of output current
70
A
Sets the range of the error: outside
the range of output current
(Err790, Err791).
If the output current is within the
range of welding current command
±
C29, the error is not issued. If it
exceeds the range, the error:
Err790, Err791 is issued.
C30
Reserved for system
80
Do not change.
C31
running time of Cooling Fan
after welding
900
s
When setting 30000(max
value),Cooling Fan always runs.
C32
Digital Meter Display during
stanby
0
Set Digital meter display during
stanby.
0: Displays setting conditions.
1: Displays stanby status
(0.0V,0A,0.0m/min)
Display
No.
Contents
Default
Setting
Unit
Description