Maintenance and inspection
9
-
55
1. Turn the robot controller to the main power supply (see Fig. 9-5: "Main power switch in
Fig. 9-5: Main power switch in "switch-off" position
2. Remove the fixing screws from the cover plate.
3. Carefully pull out the battery pack from the base.
NOTICE
The absolute encoder data will be lost
Removing the battery pack, make sure you not to remove the plug from circuit board.
4. Connect the new battery pack to the unoccupied connector on the board.
Fig. 9-6: Battery pack connections
5. Remove the old battery pack from the battery holder.
6. Mount the new battery pack to the battery holder.
NOTICE
The absolute encoder data will be lost
Never remove old battery pack before having installed new battery pack.
Main power switch in "switch-off" position
Old battery pack before replacement
Plug
New battery pack
Circuit board
See exchange, step 6
See exchange, step 7
with power ON.
WARNING
Do not open the door
High Voltage
1
1
5
1
2
3
6
4
1
4
2
5
3
6
Summary of Contents for MPL160-J00
Page 1: ...ROBOTICS MPL160 J00 YR MPL0160 J00 Operating and Maintenance Manual...
Page 36: ...Technical data 6 36 6 5 1 2 Stop position L axis 100 deflection deg deg s deg s sec...
Page 37: ...Technical data 6 37 6 5 1 3 Stop position U axis 100 deflection deg deg s deg s sec...
Page 61: ...Maintenance and inspection 9 61 Air outlet cap Joint 80 9 0 170 1 1 2 2 2 1 2...
Page 91: ...Parts lists 11 91...