Precautions for CE Low Voltage Directive Compliance
This regenerative unit has been tested according to European standard IEC/EN 61800-5-1:2007, and it fully complies
with the Low Voltage Directive.
Do not use regenerative unit in areas with pollution degree 2 and overvoltage category III in accordance with IEC/EN
60664.
Ground the neutral point of the main power supply for 400 V Class regenerative units.
Do not restart the regenerative unit or immediately operate the peripheral devices if a fuse is open or an RCD is
tripped.
Check the wiring and the selection of peripheral devices to identify the cause.
Contact your supplier before restarting the regenerative unit or the peripheral devices if the cause cannot be identified.
Do not expose the regenerative unit to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the regenerative unit.
Do not pack the regenerative unit in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.