7 Parameter Table
YASKAWA ELECTRIC
TOEP C710656 09D YASKAWA Power Regenerative Unit - R1000 Quick Start Guide
25
7
Parameter Table
This parameter table shows the most important parameters.
Default settings are bold type. Refer to the Technical
Manual for a complete list of parameters.
No.
(Addr.
Hex)
Name
Description
A1: Initialization
A1-00
(100H)
Language
Selection
0: English
1: Japanese
7: Chinese
A1-01
(101H)
Access Level
Selection
0: View and set A1-01 and A1-04.
U
-
parameters can also be viewed.
1: User Parameters (access to a set of
parameters selected by the user, A2-01 to
A2-32)
2: Advanced Access (access to view and
set all parameters)
A1-03
(103H)
Initialize
Parameters
0: No initialization
1110: User Initialize (parameter values
must be stored using parameter o2-03)
2220: 2-Wire initialization
3330: 3-Wire initialization
5550: oPE04 error reset
A1-04
(104H)
Password
When the value set into A1-04 does not
match the value set into A1-05, parameters
A1-01, A1-03, and A2-01 through A2-33
cannot be changed.
A1-05
(105H)
Password
Setting
A2: User Parameters
A2-01 to
A2-32
(106H to
125H)
User Parameters
1 to 32
Recently edited parameters are listed here.
The user can also select parameters to
appear here for quicker access.
A2-33
(126H)
User Parameter
Automatic
Selection
0: Parameters A2-01 to A2-32 are
reserved for the user to create a list of
User Parameters.
1: Save history of recently viewed
parameters. Recently edited parameters
will be saved to A2-17 through A2-32 for
quicker access.
b1: Operation Mode Selection
b1-02
(181H)
Run Command
Selection 1
0: Digital operator
1: Digital input terminals
2: MEMOBUS/Modbus communications
3: Option PCB
b1-06
(185H)
Digital Input
Reading
0: Input status is read once and processed
immediately (for quicker response)
1: Input is read twice and processed
only if the status is the same in both
readings (robust against noisy signals)
b1-08
(187H)
Run Command
Selection in
Programming
Mode
0: Run command is not accepted while
in Programming Mode.
1: Run command is accepted while in
Programming Mode.
2: Prohibit entering Programming Mode
during run.
b1-17
(1C6H)
Run Command
at Power Up
0: Disregarded. A new Run Command
must be issued.
1: Allowed. Regenerative Unit will start
immediately if Run Command is present at
power up.
b4: Timer Function
b4-01
(1A3H)
Timer Function
On-Delay Time
Sets the on-delay times for a digital timer
output (H2-
= 12).
The output is triggered by a digital input
programmed to H1-
= 18.
b4-02
(1A4H)
Timer Function
Off-Delay Time
Sets the off-delay times for a digital timer
output (H2-
= 12).
The output is triggered by a digital input
programmed to H1-
= 18.
H1: Multi-Function Digital Inputs
H1-01 to
H1-08
(438H to
405H)
Multi-Function
Digital Input
Terminal S1 to
S8 Function
Selection
Assigns a function to the multi-function
digital inputs S1 to S8.
Note:
Set unused terminals to F.
H2: Multi-Function Relay Outputs
H2-01
(40BH)
Terminal
M1-M2
Function
Selection
(Relay)
Set the functions for the relay outputs.
Refer to the Technical Manual for a
description of setting values.
Note:
Set unused terminals to F.
H2-02
(40CH)
Terminal
M3-M4
Function
Selection
(Relay)
H2-03
(40DH)
Terminal
M5-M6
Function
Selection
(Relay)
H2-06
(437H)
kWh Monitor
Pulse Output
Unit Selection
1: 1 kWh Units
2: 10 kWh Units
3: 100 kWh Units
4: 1000 kWh Units
H3: Multi-Function Analog Inputs
H3-01
(410H)
Terminal A1
Signal Level
Selection
0: 0 to 10 V
1: -10 to 10 V
H3-02
(434H)
Terminal A1
Function
Selection
Sets the function of terminal A1.
H3-03
(411H)
Terminal A1
Gain Setting
Sets the level of the input value selected in
H3-02 when 10 V is input at terminal A1.
H3-04
(412H)
Terminal A1
Bias Setting
Sets the level of the input value selected in
H3-02 when 0 V is input at terminal A1.
H3-05
(413H)
Terminal A3
Signal Level
Selection
0: 0 to 10 V
1: -10 to 10 V
H3-06
(414H)
Terminal A3
Function
Selection
Sets the function of terminal A3.
H3-07
(415H)
Terminal A3
Gain Setting
Sets the level of the input value selected in
H3-06 when 10 V is input at terminal A3.
H3-08
(416H)
Terminal A3
Bias Setting
Sets the level of the input value selected in
H3-06 when 0 V is input at terminal A3.
No.
(Addr.
Hex)
Name
Description