6.9 Welding Ground System
RM2-755-RDR Postioner
6.9.2 Weld Ground Brush Replacement
To replace the grounding brush(s) proceed as follows:
1. Shut down cell using main disconnect.
2. Remove the back panel of the drive assembly.
3. Use a flathead screwdriver to disconnect the brush cable(s) from the
ground post (
).
Fig. 6
-
5: Brush Cable Post
4. Release the spring tensioner on the brush by squeezing both spring
levers and pulling away from the faceplate.
GROUND POST
GROUND BRUSH
CABLE