6.19 EasyFFT (Fn206)
6-35
6
Utility Functions (Fn
)
(2) Related Parameters
The Easy FFT related parameters are listed below. These parameters will be automatically set and the user
need not set them manually.
Parameter
Meaning
When Enabled Classification
Pn408
n.
0
Disables 1st notch filter. (Factory setting)
Immediately
Setup
n.
1
Uses 1st notch filter.
n.
0
Disables 2nd notch filter. (Factory setting)
n.
1
Uses 2nd notch filter.
Pn409
1st Notch FIlter Frequency
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
50 to 5000
1 Hz
5000
Immediately
Tuning
Pn40C
2nd Notch FIlter Frequency
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
50 to 5000
1 Hz
5000
Immediately
Tuning
Pn456
Sweep Force Reference Amplitude
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 800
1%
15
Immediately
Tuning
Speed
Position
Force
Speed
Position
Force
Speed
Position
Force