9.3 Parameter Recording Table
9-25
9
Appendix
Pn13D
2000%
Current Gain Level
Immediately
Pn140
0100
Model Following Control Related
Switch
Immediately
Pn141
50.0/s
Model Following Control Gain
Immediately
Pn142
100.0%
Model Following Control Gain Com-
pensation
Immediately
Pn143
100.0%
Model Following Control Bias
(Forward Direction)
Immediately
Pn144
100.0%
Model Following Control Bias
(Reverse Direction)
Immediately
Pn145
50.0 Hz
Vibration Suppression 1 Frequency A
Immediately
Pn146
70.0 Hz
Vibration Suppression 1 Frequency B
Immediately
Pn147
100.0%
Model Following Control Speed
Feedforward Compensation
Immediately
Pn148
50.0/s
2nd Model Following Control Gain
Immediately
Pn149
100.0%
2nd Model Following Control Gain
Compensation
Immediately
Pn14A
80.0 Hz
Vibration Suppression 2 Frequency
Immediately
Pn14B
100%
Vibration Suppression 2 Compensa-
tion
Immediately
Pn14F
0011
Reserved Parameter
−
Pn160
0010
Anti-Resonance Control Related
Switch
Immediately
Pn161
100.0 Hz
Anti-Resonance Frequency
Immediately
Pn162
100%
Anti-Resonance Gain Compensation
Immediately
Pn163
0%
Anti-Resonance Damping Gain
Immediately
Pn164
0.00 ms
Anti-Resonance Filter Time Constant
1 Compensation
Immediately
Pn165
0.00 ms
Anti-Resonance Filter Time Constant
2 Compensation
Immediately
Pn170
1401
Tuning-less Function Related Switch
−
Pn181
0 mm/s
Mode Switch (Speed Reference)
Immediately
Pn182
0 mm/s
2
Mode Switch (Acceleration)
Immediately
Pn190
0010
Reserved Parameter
–
Pn200
0100
Reserved Parameter
–
Pn207
0010
Position Control Function Switch
After restart
Pn20E
4
Electronic Gear Ratio (Numerator)
After restart
Pn210
1
Electronic Gear Ratio (Denominator)
After restart
Pn216
0
Reserved Parameter
–
Pn217
0
Reserved Parameter
–
Pn281
1 pulse/pitch
Encoder Output Resolution
After restart
Pn282
0.00
μ
m
Linear Scale Pitch
After restart
Pn300
600
Reserved Parameter
–
Pn301
100
Reserved Parameter
–
Pn302
200
Reserved Parameter
–
Pn303
300
Reserved Parameter
–
Pn305
0 ms
Soft Start Acceleration Time
Immediately
Pn306
0 ms
Soft Start Deceleration Time
Immediately
Pn307
40
Reserved Parameter
–
Parame-
ter
Factory
Setting
Name
When