2 Panel Display and Operation of Digital Operator
2.3.3 Parameter Setting Methods
2-6
(2) Setting Method for Selection Parameters
The following example shows how to use application function selection switch 1 (Pn001) to change the setting
for the stopping method at servo OFF and alarm occurrence from stopping using DB (Pn001 = n.0000) to
stopping without DB (Pn001 = n.0002).
Step
Display after Operation
Keys
Description
1
Press the
Key to select the Parameter/Monitor
Mode.
2
Press the
or
Key to move the cursor to
“Un.”
3
Press the
or
Key to change “Un” to “Pn.”
4
Press the
Key three times to move the cursor to
the left of “=.”
5
Press the
Key to display “Pn001.”
6
Press the
Key to move the cursor to the right
edge.
7
Press the
Key twice to change the setting of
“n.0000” to “n.0002.”
8
Press the
Key to write the settings.
㧮㧮ޓޓޓޓޓޓ㧙㧼㧾㧹㧛㧹㧻㧺㧙