3 Wiring and Connection
3.2.1 I/O Signal (CN1) Names and Functions
3-18
3.2
I/O Signal Connections
This section describes the names and functions of I/O signals (CN1). Also, connection examples by control
method are shown.
3.2.1
I/O Signal (CN1) Names and Functions
The following table shows the names and functions of I/O signals (CN1).
(1) Input Signals
∗
Refer to the manual of the connected Command Option Module for information on how to allocate and use I/O signals.
Note 1. The functions allocated to /SI3, P-OT, N-OT, /SI4, /SI5, and /SI6 input signals can be changed by using the
parameters. Refer to
3.3.1 Input Signal Allocations
.
2. If the Forward run prohibited/Reverse run prohibited function is used, the software can be used to stop the SER-
VOPACK. If the application does not satisfy the safety requirements, add an external circuit for safety reasons as
required.
(2) Output Signals
Note: For more information on the allocation of /SO1, /SO2, and /SO3, refer to
3.3.2 Output Signal Allocation.
Signal
Pin No.
Name
Function
Refer-
ence
Section
/SI3
9
Command Option
Module input 3
Connects the external input signal
*
used in the Command
Option Module.
−
P-OT
7
Forward run
prohibited
Overtravel prohibited: Stops linear servomotor when mov-
able part travels beyond the allowable range of motion.
4.2.2
N-OT
8
Reverse run
prohibited
/SI4
10
Command Option
Module input 4
Connects the external input signal
*
used in the Command
Option Module.
−
/SI5
11
Command Option
Module input 5
/SI6
12
Command Option
Module input 6
+24VIN
6
Control power sup-
ply input for
sequence signal
Control power supply input for sequence signals.
Allowable voltage fluctuation range: 11 to 25 V
Note: The
+
24-V power supply is not included.
3.4.1
/SI0
13
General-purpose
input
Connects the external input signal
*
used in the Command
Option Module.
−
Signal
Pin No.
Name
Function
Refer-
ence
Section
ALM+
3
Servo alarm output
Turns OFF when an error is detected.
−
ALM-
4
/BK+
(/SO1+)
1
Brake output
Controls the brake. The brake is released when the signal
turns ON.
Allocation can be changed to general-purpose output signals
(/SO1+, /SO1-).
4.2.3
/BK-
(/SO1-)
2
/SO2+
23
General-purpose
output
General-purpose output signals
Note: Set the parameters to allocate functions.
−
/SO2-
24
/SO3+
25
/SO3-
26
SG
16
Signal ground
0 V of control circuit
−
FG
Connec-
tor shell
Frame ground
Connected to frame ground if the shield wire of the I/O signal
cable is connected to the connector shell.
−