5.1 FT40 Specification
5.1.7 Troubleshooting Based on the Operation and Conditions of the Servomotor
5-50
Servomotor
Does Not
Start
A failure occurred in the SER-
VOPACK.
–
Replace the SERVO-
PACK.
–
The polarity detection was
not executed.
Check the setting of
Pn080 =n.
X (Polar-
ity Sensor Selection).
Correct the parameter
setting.
*
Check the inputs to the
SV_ON (Servo ON) com-
mand.
•
If you are using an
incremental linear
encoder, send the
SV_ON (Servo ON)
command from the
host controller.
•
If you are using an
absolute linear
encoder, execute
polarity detection.
*
Servomotor
Moves
Instanta-
neously,
and Then
Stops
There is a mistake in the Ser-
vomotor wiring.
Check the wiring.
Wire the Servomotor
correctly.
–
There is a mistake in the wir-
ing of the encoder or Serial
Converter Unit.
Check the wiring.
Wire the Serial Con-
verter Unit correctly.
–
There is a mistake in the lin-
ear encoder wiring.
Check the wiring.
Wire the connections
correctly.
–
The setting of Pn282 (Linear
Encoder Scale Pitch) is not
correct.
Check the setting of
Pn282.
Correct the setting of
Pn282.
*
The count-up direction of the
linear encoder does not
match the forward direction
of the Moving Coil in the
motor.
Check the directions.
Change the setting of
Pn080 = n.
X
(Motor Phase
Sequence Selection).
Match the linear
encoder direction and
motor direction.
*
Polarity detection was not
performed correctly.
Check to see if electrical
angle 2 (electrical angle
from polarity origin) at any
position is between
±
10
°
.
Correct the settings for
the polarity detection-
related parameters.
–
Servomotor
Speed Is
Unstable
There is a faulty connection
in the Servomotor wiring.
The connector connec-
tions for the power line
(U, V, and W phases) and
the encoder or Serial
Converter Unit may be
unstable. Check the wir-
ing.
Tighten any loose ter-
minals or connectors
and correct the wiring.
–
Servomotor
Moves with-
out a Refer-
ence Input
A failure occurred in the SER-
VOPACK.
–
Replace the SERVO-
PACK.
–
The count-up direction of the
linear encoder does not
match the forward direction
of the Moving Coil in the
motor.
Check the directions.
Change the setting of
Pn080 = n.
X
(Motor Phase
Sequence Selection).
Match the linear
encoder direction and
Servomotor direction.
*
Polarity detection was not
performed correctly.
Check to see if electrical
angle 2 (electrical angle
from polarity origin) at any
position is between
±
10
°
.
Correct the settings for
the polarity detection-
related parameters.
–
Continued on next page.
Continued from previous page.
Problem
Possible Cause
Confirmation
Correction