6.2 FT40 Specification
6.2.1 List of Servo Parameters
6-24
Pn4AD
2
Reserved parameter (Do
not change.)
–
–
0000
All
–
–
–
Pn4D0
2
Reserved parameter (Do
not change.)
–
–
0
All
–
–
–
Pn4D1
2
Reserved parameter (Do
not change.)
–
–
0
All
–
–
–
Pn502
2
Rotation Detection Level
1 to 10,000
1 min
-1
20
Rotary
Immedi-
ately
Setup
*1
Pn503
2
Speed Coincidence
Detection Signal Output
Width
0 to 100
1 min
-1
10
Rotary
Immedi-
ately
Setup
*1
Pn506
2
Brake Reference-Servo
OFF Delay Time
0 to 50
10 ms
0
All
Immedi-
ately
Setup
*1
Pn507
2
Brake Reference Out-
put Speed Level
0 to 10,000
1 min
-1
100
Rotary
Immedi-
ately
Setup
*1
Pn508
2
Servo OFF-Brake Com-
mand Waiting Time
10 to 100
10 ms
50
All
Immedi-
ately
Setup
*1
Pn509
2
Momentary Power Inter-
ruption Hold Time
20 to 50,000
1 ms
20
All
Immedi-
ately
Setup
*1
Pn50A
2
Input Signal Selections
1
0000h to
FFF2h
–
1881h
All
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
P-OT (Forward Drive Prohibit) Signal Allocation
0
Enable forward drive when CN1-13 input signal is ON (closed).
1
Enable forward drive when CN1-7 input signal is ON (closed).
2
Enable forward drive when CN1-8 input signal is ON (closed).
3
Enable forward drive when CN1-9 input signal is ON (closed).
4
Enable forward drive when CN1-10 input signal is ON (closed).
5
Enable forward drive when CN1-11 input signal is ON (closed).
6
Enable forward drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit forward drive.
8
Set the signal to always enable forward drive.
9
Enable forward drive when CN1-13 input signal is OFF (open).
A
Enable forward drive when CN1-7 input signal is OFF (open).
B
Enable forward drive when CN1-8 input signal is OFF (open).
C
Enable forward drive when CN1-9 input signal is OFF (open).
D
Enable forward drive when CN1-10 input signal is OFF (open).
E
Enable forward drive when CN1-11 input signal is OFF (open).
F
Enable forward drive when CN1-12 input signal is OFF (open).
Summary of Contents for SERVOPACK Sigma 7 Series
Page 52: ...3 7 Monitoring 3 23 ...