6.2 FT40 Specification
6.2.1 List of Servo Parameters
6-46
Pn868
2
SVCMD_IO Output Sig-
nal Monitor Allocations
1
0000h to
1717h
–
0000h
All
Immedi-
ately
Setup
*2
Pn869
2
SVCMD_IO Output Sig-
nal Monitor Allocations
2
0000h to
1717h
–
0000h
All
Immedi-
ately
Setup
*2
Pn880
2
Station Address Moni-
tor (for maintenance,
read only)
03h to
EFh
–
–
All
–
Setup
–
Pn881
2
Set Transmission Byte
Count Monitor [bytes]
(for maintenance, read
only)
17, 32, 48
–
–
All
–
Setup
–
Pn882
2
Transmission Cycle Set-
ting Monitor [
×
0.25
μ
s]
(for maintenance, read
only)
0h to FFFFh
–
–
All
–
Setup
–
Pn883
2
Communications Cycle
Setting Monitor [trans-
mission cycles] (for
maintenance, read only)
0 to 32
–
–
All
–
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
M3
*8
n.
X
Output Signal Monitor Allocation for CN1-1 and CN1-2 (SVCMD_IO)
0
Allocate bit 24 (IO_STS1) to CN1-1/CN1-2 output signal monitor.
1
Allocate bit 25 (IO_STS2) to CN1-1/CN1-2 output signal monitor.
2
Allocate bit 26 (IO_STS3) to CN1-1/CN1-2 output signal monitor.
3
Allocate bit 27 (IO_STS4) to CN1-1/CN1-2 output signal monitor.
4
Allocate bit 28 (IO_STS5) to CN1-1/CN1-2 output signal monitor.
5
Allocate bit 29 (IO_STS6) to CN1-1/CN1-2 output signal monitor.
6
Allocate bit 30 (IO_STS7) to CN1-1/CN1-2 output signal monitor.
7
Allocate bit 31 (IO_STS8) to CN1-1/CN1-2 output signal monitor.
n.
X
CN1-1/CN1-2 Output Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-1/CN1-2 output signal monitor.
1
Enable allocation for CN1-1/CN1-2 output signal monitor.
n.
X
Output Signal Monitor Allocation for CN1-23 and CN1-24 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-1/CN1-2 allocations.
n.X
CN1-23/CN1-24 Output Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-23/CN1-24 output signal monitor.
1
Enable allocation for CN1-23/CN1-24 output signal monitor.
M3
*8
n.
X
Output Signal Monitor Allocation for CN1-25 and CN1-26 (SVCMD_IO)
0 to 7
The settings are the same as the CN1-1/CN1-2 allocations.
n.
X
CN1-25/CN1-26 Output Signal Monitor Enable/Disable Selection
0
Disable allocation for CN1-25/CN1-26 output signal monitor.
1
Enable allocation for CN1-25/CN1-26 output signal monitor.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)