8.7 Autotuning with a Host Reference
8.7.7 Related Parameters
8-40
8.7.7
Related Parameters
The following parameters are automatically adjusted or used as reference when you execute
autotuning with a host reference.
Do not change the settings while autotuning with a host reference is being executed.
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Parameter
Name
Automatic Changes
Pn100 (2100 hex)
Speed Loop Gain
Yes
Pn101 (2101 hex)
Speed Loop Integral Time Constant
Yes
Pn102 (2102 hex)
Position Loop Gain
Yes
Pn103 (2103 hex)
Moment of Inertia Ratio
No
Pn121 (2121 hex)
Friction Compensation Gain
Yes
Pn123 (2123 hex)
Friction Compensation Coefficient
Yes
Pn124 (2124 hex)
Friction Compensation Frequency Correction
No
Pn125 (2125 hex)
Friction Compensation Gain Correction
Yes
Pn401 (2401 hex)
First Stage First Torque Reference Filter Time Constant
Yes
Pn408 (2408 hex)
Torque-Related Function Selections
Yes
Pn409 (2409 hex)
First Stage Notch Filter Frequency
Yes
Pn40A (240A hex)
First Stage Notch Filter Q Value
Yes
Pn40C (240C hex)
Second Stage Notch Filter Frequency
Yes
Pn40D (240D hex)
Second Stage Notch Filter Q Value
Yes
Pn140 (2140 hex)
Model Following Control-Related Selections
Yes
Pn141 (2141 hex)
Model Following Control Gain
Yes
Pn142 (2142 hex)
Model Following Control Gain Correction
Yes
Pn143 (2143 hex)
Model Following Control Bias in the Forward Direction
Yes
Pn144 (2144 hex)
Model Following Control Bias in the Reverse Direction
Yes
Pn145 (2145 hex)
Vibration Suppression 1 Frequency A
Yes
Pn146 (2146 hex)
Vibration Suppression 1 Frequency B
Yes
Pn147 (2147 hex)
Model Following Control Speed Feedforward Compensation
Yes
Pn160 (2160 hex)
Anti-Resonance Control-Related Selections
Yes
Pn161 (2161 hex)
Anti-Resonance Frequency
Yes
Pn163 (2163 hex)
Anti-Resonance Damping Gain
Yes