4 SERVOPACK Specifications and Dimensional Drawings
4.1.3 Single-phase 220 V (Option)
4-4
4.1.3 Single-phase 220 V (Option)
The value of the input power supply voltage is maximum 253 Vrms.
* When a power supply of 187V (-15
%
of 220V) or less is used, alarm 41 which indicates voltage short-
age, may occur when accelerating to maximum speed with maximum torque of servomotor.
4.1.4 Three-phase 400 V
The value of the input power supply voltage is maximum 528 Vrms.
SERVOPACK Model SGDH-
08AE-S
15AE-S
Max. Applicable Servomotor
Capacity (kW)
0.75
1.5
Continuous Output Current
(Arms)
5.7
11.6
Max. Output Current (Arms)
13.9
28
Input Power
Supply
Main Circuit
Single-phase/Three-phase 220 to 230 VAC
+
10 to -15
%
, 50/60 Hz
∗
Control Circuit
Single-phase 220 to 230 VAC
+
10 to -15
%
, 50/60 Hz
Configuration
Base-mounted (Rack mounting available as an option)
Regenerative Processing
Built-in
SERVOPACK Model SGDH-
05D
10D
15D
20D
30D
50D
60D
75D
1AD
1ED
Max. Applicable Servomotor
Capacity (kW)
0.45
1.0
1.5
2.0
3.0
5.0
6.0
7.5
11
15
Continuous Output Current
(Arms)
1.9
3.5
5.4
8.4
11.9
16.5
20.8
25.4
28.1
37.2
Max. Output Current (Arms)
5.5
8.5
14
20
28
40.5
55
65
70
85
Input Power
Supply
Main Circuit
Three-phase 380 to 480 VAC
+
10 to -15
%
, 50/60 Hz
Control Circuit
24 VDC
±
15
%
Configuration
Base-mounted
(Rack mounting available as an option)
Base-mounted (Duct-venti-
lated available as an option)
Regenerative Processing
Built-in
External regenerative resistor
Summary of Contents for SGDH