6.1 Wiring Main Circuit
6-3
6
* 1. SGDH-08AE-S SERVOPACK (for SGMAH-08A, SGMPH-08A Servomotor) and SGDH-15AE-S
SERVOPACK (for SGMPH-15A Servomotor) have single-phase, 220 V power supply specifica-
tions. Connect the following power supply between L1 and L3.
Single-phase 220 to 230 VAC
+10%, -15%
(50/60 Hz)
If a power supply of 187 V (-15% of 220 V) or less is used, alarm 41, which indicates a voltage
shortage, may occur when accelerating to the maximum speed with the maximum torque of the
servomotor.
* 2. If using the main circuit power supply and the control power supply with DC power supply input,
refer to
6.1.3 Typical Main Circuit Wiring Examples (5) DC Power Supply Input
for more informa-
tion on wiring.
B1
,
B2
External
regenerative
resistor connection
terminal
100
0.03 to 0.2
Normally not connected.
Connect an external regenerative resistor (provided
by customer) between B1 and B2 if the regenerative
capacity is insufficient.
200
0.03 to 0.4
B1
,
B2
,
B3
200
0.5 to 5.0
Normally short B2 and B3 (for an internal regenera-
tive resistor).
Remove the wire between B2 and B3 and connect an
external regenerative resistor (provided by customer)
between B1 and B2 if the capacity of the internal
regenerative resistor is insufficient.
400
0.5 to 5.0
B1
,
B2
200
6.0 to 15.0
Connect an external regenerative resistor (provided
by customer) between B1 and B2. Refer to
6.5 Con-
necting Regenerative Resistors
for details.
400
6.0 to 15.0
1
,
2
DC reactor for
harmonic
suppression
terminal
100
0.03 to 0.2
Normally short
1 and
2 .
If a countermeasure against power supply harmonic
waves is needed, connect a DC reactor between
1
and 2.
200
0.03 to 5.0
400
0.5 to 15.0
200
6.0 or more
These terminals do not exist.
Main circuit plus
terminal
200
6.0 or more
Normally not connected.
Note: This terminal is on the SERVOPACK with a
capacity of 6.0 kW or higher only.
Main circuit minus
terminal
−
−
Normally not connected.
Terminal Symbol
Name
Main
Circuit
Voltage
(V)
Maximum
Applicable
Servomotor
Capacity
(kW)
Functions