10.1 Troubleshooting
10-3
10
* The alarm meaning differs depending on the SERVOPACK capacity.
•
For the SERVOPACK with a capacity of 5.0 kW or lower:
A.40: Overvoltage detection alarm
A.41: Undervoltage detection alarm
•
For the SERVOPACK with a capacity of 6.0 kW or higher:
A.40: Alarm detecting excessively high/low voltage in the main circuit
A.41: Not used
A.81
Encoder Backup Error
All the power supplies for the absolute
encoder have failed and position data
was cleared.
N/A
H
H
H
H
A.82
Encoder Checksum Error
The checksum results of encoder
memory is abnormal.
N/A
A.83
Absolute Encoder Battery Error
Backup battery voltage for the abso-
lute encoder has dropped.
Available
A.84
Encoder Data Error
Data in the encoder is abnormal.
N/A
A.85
Encoder Overspeed
The encoder was rotating at high
speed when the power was turned ON.
N/A
A.86
Encoder Overheated
The internal temperature of encoder is
too high.
N/A
A.b1
Reference Speed Input Read Error
The A/D converter for reference speed
input is faulty.
Available
A.b2
Reference Torque Input Read Error
The A/D converter for reference
torque input is faulty.
Available
A.bF
System Alarm
A system error occurred in the SER-
VOPACK.
N/A
A.C1
Servo Overrun Detected
The servomotor ran out of control.
Available
L
H
L
H
A.C8
Absolute Encoder Clear Error and
Multiturn Limit Setting Error
The multiturn for the absolute encoder
was not properly cleared or set.
N/A
A.C9
Encoder Communications Error
Communications between SERVO-
PACK and encoder is not possible.
N/A
A.CA
Encoder Parameter Error
Encoder parameters are faulty.
N/A
A.Cb
Encoder Echoback Error
Contents of communications with
encoder is incorrect.
N/A
A.CC
Multiturn Limit Disagreement
Different multiturn limits have been
set in the encoder and SERVOPACK.
N/A
A.d0
Position Error Pulse Overflow
Position error pulse exceeded parame-
ter (Pn505).
Available
L
L
H
H
A.E7
Application Module Detection Error
The application module detection
fails.
Available
H
L
L
H
A.F1
Power Line Open Phase
One phase is not connected in the
main power supply.
Available
H
L
H
H
CPF00
Digital Operator
Transmission Error
Digital operator (JUSP-OP02A-2)
fails to communicate with SERVO-
PACK (e.g., CPU error).
N/A
Not decided
CPF01
N/A
A.
− −
Not an error
Normal operation status
−
H
H
H
L
Table 10.1 Alarm Displays and Outputs (Cont’d)
Alarm
Display
Alarm Name
Meaning
Alarm
Reset
Alarm Code Output
Servo
Alarm
(ALM)
Output
ALO1
ALO2
ALO3
Summary of Contents for SGDH
Page 435: ...8 3 8...