6 Wiring
6.3.6 Interface Circuit
6-16
(b) Open-collector Output Circuit
CN1 connector terminals 30 to 33: Alarm code output are explained below.
Alarm code signals (ALO1, ALO2, ALO3) are output from open-collector transistor output circuits. Con-
nect an open-collector output circuit through a photocoupler, relay circuit, or line receiver circuit.
Note: The maximum allowable voltage and current capacities for open-collector output circuits
are as follows:
• Voltage: 30 VDC
• Current: 20 mA DC
(c) Photocoupler Output Circuit
Photocoupler output circuits are used for servo alarm (ALM), servo ready (/S-RDY), and other sequence out-
put signal circuits. Connect a photocoupler output circuit through a relay circuit or line receiver circuit.
Note: The maximum allowable voltage and current capacities for photocoupler output circuits
are as follows:
• Voltage: 30 VDC
• Current: 50 mA DC
Photocoupler Circuit Example
Relay Circuit Example
Line Receiver Circuit Example
0 V
0 V
SERVOPACK
5 to 12 VDC
Photocoupler
0 V
Relay
5 to 24 VDC
SERVOPACK
SERVOPACK
5 to 12 VDC
0 V
0 V
Relay Circuit Example
Line Receiver Circuit Example
0 V
Relay
5 to 24 VDC
SERVOPACK
5 to 12 VDC
SERVOPACK
0 V