10.4 List of Parameters
10-35
10
* Used only for SGDJ-
P SERVOPACK for position control mode.
Pn003
Function Selection Application Switches 3
−
−
0002
0002
Immedi-
ately
−
Pn004
Reserved (Do not change)
−
−
0000
0000
Immedi-
ately
−
Pn005
Reserved (Do not change)
−
−
0000
0000
Immedi-
ately
−
Pn100
Speed Loop Gain
1 to 2000 Hz
1 Hz
40
40
Immedi-
ately
9.3.4
Pn101
Speed Loop Integral Time Constant
0.15 to 512.00 ms
0.01 ms
2000
2000
Immedi-
ately
9.3.5
Pn102
Position Loop Gain *
1 to 2000/s
1/s
−
40
Immedi-
ately
9.3.3
Pn103
Moment of Inertia Ratio
0 to 10000%
1%
0
0
Immedi-
ately
9.2.6
9.3.3
Pn104
2nd Speed Loop Gain
1 to 2000 Hz
1 Hz
40
40
Immedi-
ately
9.4.8
Pn105
2nd Speed Loop Integral Time Constant
0.15 to 512.00 ms
0.01 ms
2000
2000
Immedi-
ately
9.4.8
Pn106
2nd Position Loop Gain *
1 to 2000/s
1/s
−
40
Immedi-
ately
9.4.8
Pn107
Bias *
0 to 450 min
-1
1 min
-1
−
0
Immedi-
ately
9.4.5
Pn108
Bias Width Addition *
0 to 250 reference
units
Reference
unit
0
7
Immedi-
ately
9.4.5
Pn109
Feed-forward *
0 to 100%
1%
−
0
Immedi-
ately
9.4.1
Param-
eter No.
Name
Setting Range
Units
Factory Setting
Setting
Validation
Reference
Section
S
P
0
1
2
3
4
5
6
7
Motor speed: 1 V/1000 min
-1
Speed reference: 1 V/1000 min
-1
Torque reference: 1 V/100%
Position error: 0.05 V/1 reference unit *
Position error: 0.05 V/100 reference units *
Reference pulse frequency (converted to min
-1
): 1 V/1000 min
-1
Motor speed
×
4: 1 V/250 min
-1
Motor speed
×
8: 1 V/150 min
-1
Reserved (Do not change)
Analog Monitor 1 Torque Reference Monitor
(Refer to "9.5 Analog Monitor.")
0 to F
Same as Analog Monitor 1 Torque Reference Monitor
Analog Monitor 2 Speed Reference Monitor
(Refer to "9.5 Analog Monitor.")
4th
digit
3rd
digit
2nd
digit
1st
digit
n.
8 to F
Reserved (Do not change)
Reserved (Do not change)