9.3 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor
9-29
9
Trou
blesh
ooting
Dynamic Brake
Does Not Operate
Improper Pn001.0 setting
Check the setting for parameter
Pn001.0.
Correct the setting for parameter
Pn001.0.
DB resistor disconnected
Check if excessive moment of iner-
tia, motor overspeed, or DB fre-
quently activated occurred.
Replace the dynamic brake unit or
change the external dynamic brake
circuit. And reduce the load.
DB drive circuit fault
−
A defective component is in the
dynamic brake circuit inside SER-
VOPACK. Replace the SERVO-
PACK.
Wiring of the dynamic brake unit is
incorrect.
Check the wiring.
Correct the wiring.
(cont’d)
Problem
Probable Cause
Investigative Actions
Corrective Actions