4 Safety Function
4-4
4.3
Safety Function Signal (CN8) Names and Functions
The following table shows the terminal layout of safety function signals (CN8).
∗
Do not use unused terminals. (connected to the internal circuits)
4.4
Precautions When Not Using the Safety Function
When not using the safety function or when performing a JOG operation, use the
SERVOPACK with the safety function jumper connector (JZSP-CVH05-E, provided
as an accessory) inserted. If the SERVOPACK is used without the jumper connector
inserted into CN8, no current will flow to the motor and no torque will be output.
When Hbb is displayed on the panel operator and digital operator, the motor is base-
blocked by the safety function. Check to see if the JZSP-CVH05-E jumper connector
is correctly inserted into CN8.
Pin No.
Signal
Name
Function
1
*
−
−
−
2
*
−
−
−
3
/HWBB1-
Hard wire baseblock input 1
Hard wire baseblock input
Baseblock (motor current off)
when OFF
4
/HWBB1+
5
/HWBB2-
Hard wire baseblock input 2
6
/HWBB2+
7
EDM1-
Monitored circuit status output 1
ON when the /HWBB1 and the
/HWBB2 signals are input and
the SERVOPACK enters a
baseblock state.
8
EDM1+