DIFFERENCES BETWEEN DR2 AND DR1, SGDA AND SGD SERVOPACKS
426
Comparison of the DR2 Servopack with the DR1 Servopack (2)
Item
DR2 Servopack
DR1 Servopack
Remarks
Type
DR2-
jj
AC
(Semi-closed type)
DR2-
jj
AC-F
(Full-closed type)
DR1-
jj
AC
(Incremental type)
DR1-
jj
AA
(Absolute type)
As for DR2, factory
setting of applicable
motor is SGM
Servomotor.
DR2-
jj
ACP
(Semi-closed type)
DR2-
jj
ACP-F
(Full-closed type)
−
Factory setting of
applicable motor is
SGMP Servomotor.
Outside Dimensions
60W
×
250H
×
204D
(200V: 30W to 200W)
(100V: 30W to 100W)
60W
×
250H
×
250D
(200V: 30W to 200W)
(100V: 30W to 100W)
Mounting hole position
is in common with DR2
and DR1.
75W
×
250H
×
252D
(200V: 400W and
750W)
(100V: 200W and
300W)
75W
×
250H
×
250D
(200V: 400W and
750W)
(100V: 200W)
Base-mount type
Option
No
Motor Terminals
External terminals in
conformance with
Standard
(PHOENIX CONTACT)
External terminal
(M4 screw)
Encoder Connector 2CN
MR-20RMA
MR-20RMA
Common with DR2 and
DR1. (Different from
SGD type)
Connector 4CN for Full-closed Type
MR-8RMA
−
External I/O
Signals
Used Connector
MR-50RFA
MR-50RFA
Common with DR2 and
DR1.
S g a s
(1CN)
3-pin
PL1: PULS pull-up
SG: Signal ground
PL1, 2 and 3 are used
f
ll
f
5-pin
V-REF: Exclusive for
speed reference
input
IN-A: Main input
,
for pull-up of open
collector input.
Signals other than
9-pin
T-REF: Exclusive for
torque
reference
input
IN-B: Auxiliary input
Signals other than
described here are used
in common with DR2
and DR1.
13-pin
PL2: SIGN pull-up
SG: Signal ground
18-pin
PL3: CLR pull-up
SG: Signal ground
23-pin
+15V: Reference power
supply 30mA
PHC: Phase-C open
collector
24-pin
-15V: Reference power
supply 30mA
SG: Signal ground
A