3.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
3.4.2 List of Alarms
3-148
A.8A0
External Encoder
Error
An error occurred in the external encoder.
Gr.1
Yes
H
H
H
A.8A1
External Encoder
Module Error
An error occurred in the Serial Converter
Unit.
Gr.1
Yes
A.8A2
External Incremental
Encoder Sensor Error
An error occurred in the external encoder.
Gr.1
Yes
A.8A3
External Absolute
Encoder Position
Error
An error occurred in the position data of
the external encoder.
Gr.1
Yes
A.8A5
External Encoder
Overspeed
An overspeed error occurred in the exter-
nal encoder.
Gr.1
Yes
A.8A6
External Encoder
Overheated
An overheating error occurred in the
external encoder.
Gr.1
Yes
A.AEF
INDEXER Module
Alarm
Some kind of alarm has occurred at the
INDEXER Module.
Gr.1
Depends
on
module
alarm.
*1
H
L
L
A.b33
Current Detection
Error 3
An error occurred in the current detection
circuit.
Gr.1
No
H
H
H
A.bF0
System Alarm 0
Internal program error 0 occurred in the
SERVOPACK.
Gr.1
No
A.bF1
System Alarm 1
Internal program error 1 occurred in the
SERVOPACK.
Gr.1
No
A.bF2
System Alarm 2
Internal program error 2 occurred in the
SERVOPACK.
Gr.1
No
A.bF3
System Alarm 3
Internal program error 3 occurred in the
SERVOPACK.
Gr.1
No
A.bF4
System Alarm 4
Internal program error 4 occurred in the
SERVOPACK.
Gr.1
No
A.bF5
System Alarm 5
Internal program error 5 occurred in the
SERVOPACK.
Gr.1
No
A.bF6
System Alarm 6
Internal program error 6 occurred in the
SERVOPACK.
Gr.1
No
A.bF7
System Alarm 7
Internal program error 7 occurred in the
SERVOPACK.
Gr.1
No
A.bF8
System Alarm 8
Internal program error 8 occurred in the
SERVOPACK.
Gr.1
No
A.C10
Servomotor Out of
Control
The Servomotor ran out of control.
Gr.1
Yes
L
H
L
A.C80
Encoder Clear Error or
Multiturn Limit Set-
ting Error
The multiturn data for the absolute
encoder was not correctly cleared or set.
Gr.1
No
A.C90
Encoder Communica-
tions Error
Communications between the encoder
and SERVOPACK is not possible.
Gr.1
No
Continued on next page.
Continued from previous page.
Alarm
Number
Alarm Name
Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?
Alarm Code Output
/ALO1 /ALO2 /ALO3