3.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
3.4.8 INDEXER Module Error Displays and Troubleshooting
3
Maintenance
3-191
E49E
A.A9F
Serial Communi-
cations Framing
Error
A stop bit detection error occurred with the
serial command.
•
The command that caused this error will
be discarded and no response will be
returned.
•
There will be no response, but the
/WARN output and LED indicators will
indicate that an error has occurred.
•
Check the serial
communica-
tions protocol
(PnB00) and bit
rate (PnB01)
settings.
•
Check the wir-
ing.
•
If noise may be
causing the
problem, take
steps to reduce
noise such as
using commu-
nications
cables with fer-
rite cores.
E4AE
A.A9F
Serial Communi-
cations Overrun
Error
Serial command reception failed.
•
The hardware’s reception buffer was over-
written with the subsequent data.
(Normally, data is read before it is over-
written, so this error does not occur.)
Repair the hard-
ware.
E4BE
A.A9F
Moving Disabled
Error due to P-OT
Travel in the forward direction was
requested when P-OT was in effect. (For-
ward movement is disabled when P-OT
(forward overtravel) is in effect.)
•
When P-OT is
being used,
move to a posi-
tion where the
P-OT is not in
effect.
•
When P-OT is
not being used,
disable P-OT in
the parameter
(PnB0F = 3).
E4CE
A.A9F
Moving Disabled
Error due to N-OT
Travel in the reverse direction was
requested when N-OT was in effect.
(Reverse movement is disabled when N-OT
(reverse overtravel) is in effect.)
•
When N-OT is
being used,
move to a posi-
tion where the
N-OT is not in
effect.
•
When N-OT is
not being used,
disable N-OT in
the parameter
(PnB10 = 3).
Continued on next page.
Continued from previous page.
Serial
Command
Negative
Response
Alarm
Number
Error Name
Meaning
Corrective Action