3.5 FT83 SERVOPACKs with Analog Voltage/Pulse Train References
3.5.7 Troubleshooting Warnings
3-244
A.9A0:
Overtravel (Over-
travel status was
detected.)
Overtravel was
detected while the
servo was ON.
Check the status of the
overtravel signals on
the input signal monitor.
Even if an overtravel signal
is not shown by the input
signal monitor, momentary
overtravel may have been
detected. Take the following
precautions.
•
Do not specify move-
ments that would cause
overtravel from the host
controller.
•
Check the wiring of the
overtravel signals.
•
Implement countermea-
sures against noise.
–
A.9b0:
Preventative Mainte-
nance Warning
One of the con-
sumable parts has
reached the end
of its service life.
–
Replace the part. Contact
your Yaskawa representa-
tive for replacement.
–
A.9F9:
INDEXER Warning
A warning
occurred in the
INDEXER.
Use the S to
identify the INDEXER
warning.
Use the correction for the
INDEXER warning.
Continued from previous page.
Warning Number:
Warning Name
Possible Cause
Confirmation
Correction
Reference