4.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
4
Parameter Li
s
t
s
4-13
Pn163
2
Anti-Resonance Damp-
ing Gain
0 to 300
1%
0
All
Immedi-
ately
Tuning
*1
Pn164
2
Anti-Resonance Filter
Time Constant 1 Cor-
rection
-1,000 to
1,000
0.01 ms
0
All
Immedi-
ately
Tuning
*1
Pn165
2
Anti-Resonance Filter
Time Constant 2 Cor-
rection
-1,000 to
1,000
0.01 ms
0
All
Immedi-
ately
Tuning
*1
Pn166
2
Anti-Resonance Damp-
ing Gain 2
0 to 1,000
1%
0
All
Immedi-
ately
Tuning
*1
Pn170
2
Tuning-less Function-
Related Selections
0000h to
2711h
–
1401h
All
–
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Tuning-less Selection
When
Enabled
0
Disable tuning-less function.
After
restart
1
Enable tuning-less function.
n.
X
Speed Control Method
When
Enabled
0
Use for speed control.
After
restart
1
Use for speed control and use host controller for position control.
n.
X
Rigidity Level
When
Enabled
0 to 7
Set the rigidity level.
Immedi-
ately
n.X
Tuning-less Load Level
When
Enabled
0 to 2
Set the load level for the tuning-less function.
Immedi-