4.1 FT82 SERVOPACKs with Analog Voltage/Pulse Train References
4-30
Pn533
2
Program Jogging Move-
ment Speed
1 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1
min
-1
500
Rotary
Immedi-
ately
Setup
*1
Pn534
2
Program Jogging Accel-
eration/Deceleration
Time
2 to 10,000
1 ms
100
All
Immedi-
ately
Setup
*1
Pn535
2
Program Jogging Wait-
ing Time
0 to 10,000
1 ms
100
All
Immedi-
ately
Setup
*1
Pn536
2
Program Jogging Num-
ber of Movements
0 to 1,000
Times
1
All
Immedi-
ately
Setup
*1
Pn550
2
Analog Monitor 1 Offset
Voltage
-10,000 to
10,000
0.1 V
0
All
Immedi-
ately
Setup
*1
Pn551
2
Analog Monitor 2 Offset
Voltage
-10,000 to
10,000
0.1 V
0
All
Immedi-
ately
Setup
*1
Pn552
2
Analog Monitor 1 Mag-
nification
-10,000 to
10,000
×
0.01
100
All
Immedi-
ately
Setup
*1
Pn553
2
Analog Monitor 2 Mag-
nification
-10,000 to
10,000
×
0.01
100
All
Immedi-
ately
Setup
*1
Pn55A
2
Power Consumption
Monitor Unit Time
1 to 1,440
1 min
1
All
Immedi-
ately
Setup
−
Pn560
2
Residual Vibration
Detection Width
1 to 3,000
0.1%
400
All
Immedi-
ately
Setup
*1
Pn561
2
Overshoot Detection
Level
0 to 100
1%
100
All
Immedi-
ately
Setup
*1
Pn600
2
Regenerative Resistor
Capacity
*4
Depends on
model.
*5
10 W
0
All
Immedi-
ately
Setup
*1
Pn601
2
Dynamic Brake Resis-
tor Allowable Energy
Consumption
0 to 65,535
10 J
0
All
After
restart
Setup
*6
Pn603
2
Regenerative Resis-
tance
0 to 65,535
10 m
Ω
0
All
Immedi-
ately
Setup
*1
Pn604
2
Dynamic Brake Resis-
tance
0 to 65,535
10 m
Ω
0
All
After
restart
Setup
*6
Pn61A
2
Overheat Protection
Selections
0000h to
0003h
–
0000h
Linear
After
restart
Setup
*1
Pn61B
*8
2
Overheat Alarm Level
0 to 500
0.01 V
250
All
Immedi-
ately
Setup
*1
Pn61C
*8
2
Overheat Warning Level
0 to 100
1%
100
All
Immedi-
ately
Setup
*1
Pn61D
*8
2
Overheat Alarm Filter
Time
0 to 65,535
1 s
0
All
Immedi-
ately
Setup
*1
Pn621 to
Pn628
*3
–
Safety Module-Related
Parameters
–
–
–
All
–
–
–
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Overheat Protection Selection
0
Disable overheat protection.
1
Use overheat protection in the Yaskawa Linear Servomotor.
*7
2
Monitor a negative voltage input from a sensor attached to the machine and
use overheat protection.
3
Monitor a positive voltage input from a sensor attached to the machine and
use overheat protection.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)