4.3 FT82 SERVOPACK with MECHATROLINK-III Communications References
4.3.1 List of Servo Parameters
4-94
Pn804
4
Forward Software Limit
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
107374
1823
All
Immedi-
ately
Setup
*1
Pn806
4
Reverse Software Limit
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
-10737
41823
All
Immedi-
ately
Setup
*1
Pn808
4
Absolute Encoder Origin
Offset
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
0
All
Immedi-
ately
*11
Setup
*1
Pn80A
2
First Stage Linear Accel-
eration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*12
Setup
*2
Pn80B
2
Second Stage Linear
Acceleration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*12
Setup
*2
Pn80C
2
Acceleration Constant
Switching Speed
0 to 65,535
100 ref-
erence
units/s
0
All
Immedi-
ately
*12
Setup
*2
Pn80D
2
First Stage Linear
Deceleration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*12
Setup
*2
Pn80E
2
Second Stage Linear
Deceleration Constant
1 to 65,535
10,000
refer-
ence
units/s
2
100
All
Immedi-
ately
*12
Setup
*2
Pn80F
2
Deceleration Constant
Switching Speed
0 to 65,535
100 ref-
erence
units/s
0
All
Immedi-
ately
*12
Setup
*2
Pn810
2
Exponential Accelera-
tion/Deceleration Bias
0 to 65,535
100 ref-
erence
units/s
0
All
Immedi-
ately
*13
Setup
*2
Pn811
2
Exponential Accelera-
tion/Deceleration Time
Constant
0 to 5,100
0.1 ms
0
All
Immedi-
ately
*13
Setup
*2
Pn812
2
Movement Average
Time
0 to 5,100
0.1 ms
0
All
Immedi-
ately
*13
Setup
*2
Pn814
4
External Positioning
Final Travel Distance
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
100
All
Immedi-
ately
Setup
*2
Pn816
2
Origin Return Mode Set-
tings
0000h to
0001h
–
0000h
All
Immedi-
ately
Setup
*14
Pn817
*16
2
Origin Approach Speed
1
0 to 65,535
100 ref-
erence
units/s
50
All
Immedi-
ately
*12
Setup
*2
Pn818
*17
2
Origin Approach Speed
2
0 to 65,535
100 ref-
erence
units/s
5
All
Immedi-
ately
*12
Setup
*2
Pn819
4
Final Travel Distance for
Origin Return
-1,073,741,823
to
1,073,741,823
1 refer-
ence
unit
100
All
Immedi-
ately
Setup
*2
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
M2
*15
n.
X
Origin Return Direction
0
Return in forward direction.
1
Return in reverse direction.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)