4.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
4-132
PnB05
2
/PGMRES; /JOGP
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB06
2
/SEL0; /JOGN
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB07
2
/SEL1; /JOG0
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB08
2
/SEL2; /JOG1
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
0000h
•
When /MODE signal is ON (closed) (mode 0): Turn ON (close) the /PGMRES signal to
reset and cancel program table operation.
•
When /MODE signal is OFF (open) (mode 1): Jog forward while the /JOGP signal is ON
(closed).
0001h
•
When /MODE signal is ON (closed) (mode 0): Turn OFF (open) the /PGMRES signal to
reset and cancel program table operation.
•
When /MODE signal is OFF (open) (mode 1): Jog forward while the /JOGP signal is OFF
(open).
0002h,
0003h
•
When /MODE signal is ON (closed) (mode 0): Do not reset program table operation.
•
When /MODE signal is OFF (open) (mode 1): Do not perform jogging.
0000h
•
When /MODE signal is ON (closed) (mode 0): /SEL0 signal is active when ON (closed).
•
When /MODE signal is OFF (open) (mode 1): Jog in reverse while the /JOGP signal is ON
(closed).
0001h
•
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is active when OFF (open).
•
When /MODE signal is OFF (open) (mode 1): Jog in reverse while the /JOGN signal is OFF
(open).
0002h
•
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always active.
•
When /MODE signal is OFF (open) (mode 1): Do not perform jogging.
0003h
•
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always inactive.
•
When /MODE signal is OFF (open) (mode 1): Do not perform jogging.
0000h
•
When /MODE signal is ON (closed) (mode 0): /SEL1 signal is active when ON (closed).
•
When /MODE signal is OFF (open) (mode 1): /JOG0 signal is active when ON (closed).
0001h
•
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is active when OFF (open).
•
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is active when OFF (open).
0002h
•
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always active.
•
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always active.
0003h
•
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always inactive.
•
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always inactive.
0000h
•
When /MODE signal is ON (closed) (mode 0): /SEL2 signal is active when ON (closed).
•
When /MODE signal is OFF (open) (mode 1): /JOG1 signal is active when ON (closed).
0001h
•
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is active when OFF (open).
•
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is active when OFF (open).
0002h
•
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always active.
•
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always active.
0003h
•
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always inactive.
•
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always inactive.