4.4 Command Option Attachable-type FT82 SERVOPACKs with INDEXER Modules
4-134
PnB0F
2
P-OT
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB10
2
N-OT
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB11
2
/DEC
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB12
2
/RGRT
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB13
2
/INPOSITION
0000h to
0003h
–
0000h
All
After
restart
Setup
*1
PnB14
2
/POUT0
0000h,
0001h
–
0000h
All
After
restart
Setup
*1
PnB15
2
/POUT1
0000h,
0001h
–
0000h
All
After
restart
Setup
*1
PnB16
2
/POUT2
0000h,
0001h
–
0000h
All
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
0000h
When input signal is OFF (open), forward run is prohibited (forward overtravel).
0001h
When input signal is ON (closed), forward run is prohibited (forward overtravel).
0002h
Forward run is always prohibited (forward overtravel).
0003h
Forward run is always enabled. (P-OT signal is not used.)
0000h
When input signal is OFF (open), reverse run is prohibited (reverse overtravel).
0001h
When input signal is ON (closed), reverse run is prohibited (reverse overtravel).
0002h
Reverse run is always prohibited (reverse overtravel).
0003h
Reverse run is always enabled. (N-OT signal is not used.)
0000h
Starts deceleration in an origin return when input signal is ON (closed).
0001h
Starts deceleration in an origin return when input signal is OFF (open).
0002h
Sets the origin return limit switch always ON.
0003h
Sets the origin return limit switch always OFF.
0000h
Starts registration by switching input signal from OFF (open) to ON (closed).
0001h
Starts registration by switching input signal from ON (close) to OFF (open).
0002h,
0003h
Does not start registration.
0000h
When positioning has been completed, photocoupler becomes ON (closed).
0001h
When positioning has been completed, photocoupler becomes OFF (open).
0002h,
0003h
Reserved.
0000h
The /POUT0 signal turns ON (opens) when programmable output 0 is active.
0001h
The /POUT0 signal turns OFF (closes) when programmable output 0 is active.
0000h
The /POUT1 signal turns ON (opens) when programmable output 1 is active.
0001h
The /POUT1 signal turns OFF (closes) when programmable output 1 is active.
0000h
The /POUT2 signal turns ON (opens) when programmable output 2 is active.
0001h
The /POUT2 signal turns OFF (closes) when programmable output 2 is active.