7.2 Specifications and Ratings
7.2.4 Small-Capacity, Coreless Servomotors: Servomotor Overload Protection Characteristics
7-8
7.2.4
Small-Capacity, Coreless Servomotors: Servomotor
Overload Protection Characteristics
The overload detection level is set for hot start conditions with a Servomotor surrounding air tem-
perature of 40
°
C.
Note: The above overload protection characteristics do not mean that you can perform continuous duty operation
with an output of 100% or higher.
Use the Servomotor so that the effective force remains within the continuous duty zone. Refer to the following
section for the effective torque.
7.2.3 Small-Capacity, Coreless Servomotors: Torque-Motor Speed Characteristics
SGMCS-02B, -05B, -07B, -10C, -17D, and -35E
SGMCS-08D and -16E
Detection time (s)
Torque reference (%)
Detection time (s)
Detection time (s)
Detection time (s)
Torque reference (%)
Torque reference (%)
Torque reference (%)
Torque reference (%)
0
50
100
150
200
250
300
10000
1000
100
10
1
SGMCS-04C
0
50
100
150
200
250
300
10000
1000
100
10
1
SGMCS-14C
0
50
100
150
200
250
300
10000
1000
100
10
1
SGMCS-25D
0
50
100
150
200
250
300
10000
1000
100
10
1
0
50
100
150
200
250
300
10000
1000
100
10
1
Detection time (s)