6.3 Settings
6-9
6
6.3.3 LED 7-Segment Display
The state of the SERVOPACK is shown in the 7-segment LED display.
The status of the SERVOPACK is displayed as follow.
Only the Servo OFF light segment will light up before connecting to the network after turning on the power sup-
ply.
The following displays are alternately lit at P_OT and N_OT status.
When an alarm is generated, the alarm code digits are alternately lit as the status.
For example, “A.123”:
On: Servo is in motion
Off: Servo stopping or stopped
On: Servo ON (enabled)
Off: Servo OFF (disabled)
On: Communication history exist
Off: No communication history
On: Synchronous communications
Off: Asynchronous communications
P_OT
N_OT
Status
A
1
2
3
SIEPS80000025.book 9 ページ 2004年10月25日 月曜日 午前11時57分