8.2 Analog Monitor
8-5
8
8.2 Analog Monitor
Signals for analog voltage references can be monitored.
To monitor analog signals, connect the analog monitor cable (JZSP-CA01) to the connector CN5.
The analog monitor signals can be changed by setting parameters Pn006.0,1 and Pn007.0,1.
The output voltages on analog monitor 1 and 2 are set as shown below.
Line Color
Signal Name
Description
White
Analog monitor 1
Torque reference: 1 V/100% Rated torque
Red
Analog monitor 2
Motor speed: 1 V/1000 min
-1
Black (2 lines)
GND (0 V)
Analog monitor GND: 0 V
CN5
White
Red
Black
Black
Analog monitor 1 output voltage = {(-1)
×
Signal selection
×
Signal multiplier } + Offset voltage [V]
Pn006=
XX
Pn006= X
Pn550
Analog monitor 2 output voltage = {(-1)
×
Signal selection
×
Signal multiplier } + Offset voltage [V]
Pn007=
XX
Pn007= X
Pn551
SIEPS80000025.book 5 ページ 2004年10月25日 月曜日 午前11時57分