10.1 Utility Functions
10-9
10
* 1. Normally set to “0.” When using an external regenerative resistor, set the capacity (W) of the regenerative resistor.
* 2. The upper limit is the maximum output capacity (W) of the SERVOPACK.
Pn534
Program JOG Acceleration/Deceleration
Time
2 to 10000 ms
1 ms
100 ms
Immedi-
ately
−
Pn535
Program JOG Waiting Time
0 to 10000 ms
1 ms
100 ms
Immedi-
ately
−
Pn536
Number of Times of Program JOG Move-
ment
1 to 1000 times
1 time
1 time
Immedi-
ately
−
Pn550
Analog Monitor 1 Offset Voltage
-1000.0 to 1000.0 V
0.1 V
0.0 V
Immedi-
ately
Pn551
Analog Monitor 2 Offset Voltage
-1000.0 to 1000.0 V
0.1 V
0.0 V
Immedi-
ately
Pn600
Regenerative Resistor Capacity
∗
1
Depends on
SERVOPACK Capac-
ity
∗
2
10 W
0 W
Immedi-
ately
−
Parameter
No.
Name
Setting Range
Units
Factory
Setting
Setting
Validation
Reference
Section