3.4 SERVOPACK Power Losses
3-11
3
3.4 SERVOPACK Power Losses
The following table shows SERVOPACK power losses at the rated output.
* 1. SERVOPACKs with a capacity of 50 to 400 W do not have built-in regenerative resistors. If the
regenerative energy exceeds the specified value, connect an external regenerative resistor.
* 2. Regenerative resistor power losses are allowable losses. Take the following action if this value is
exceeded.
• Remove the lead from the internal regenerative resistor in the SERVOPACK.
• Install an external regenerative resistor.
Note: External regenerative resistors are optional. Refer to
5.5 Connecting Regenerative Resistors
4.4.6 External Regenerative Resistor
for details.
SERVOPACK Power Losses at Rated Output
Main Circuit
Power
Supply
Maximum
Applicable
Servomotor
Capacity
(kW)
SERVOPACK
Model
SGDS-
Output
Current
(Effective
Value)
(A)
Main Circuit
Power Loss
(W)
Regenerative
Resistor Power
Loss
(W)
Control
Circuit
Power
Loss
(W)
Total
Power
Loss
(W)
Single-
phase 100V
0.05
A5F
0.66
5.2
−
∗
1
13
18.2
0.10
01F
0.91
12
25
0.20
02F
2.1
16.4
29.4
0.40
04F
2.8
24
37
Single-
phase 200V
0.05
A5A
0.64
4.6
17.6
0.10
01A
0.91
6.7
19.7
0.20
02A
2.1
13.3
26.3
0.40
04A
3.8
27
40
0.75
08A
5.5
47
12
15
74
Three-
phase 200V
1.0
10A
7.6
55
12
82
1.5
15A
11.6
92
14
121
2.0
20A
18.5
120
28
163
3.0
30A
18.9
155
28
198
SIEPS80000025.book 11 ページ 2004年10月25日 月曜日 午前11時57分