4.4 Peripheral Devices
4-21
4
4.4.12 AC/DC Reactors for Harmonic Suppression
(1) Specifications
Manufactured by Yaskawa Controls Co., Ltd. Contact your Yaskawa representative for details.
If necessary for harmonic suppression, connect an AC reactor to the AC line for the single-phase input, a DC
reactor between the SERVOPACK main circuit terminals
1 and
2 for the three-phase input. Select a reactor
that matches the ratings of the SERVOPACK. For wiring, refer to
5.4.5 AC/DC Reactor for Harmonic Suppres-
.
Applicable
SERVOPACK Model
SGDS-
AC/DC Reactor
Model
Reactor Specifications
Inductance
(mH)
Rated
Current
(A)
Single-phase,
100 V
A5F
X5053
20.0
2.0
01F
X5053
20.0
2.0
02F
X5054
5.0
3.0
04F
X5056
2.0
5.0
Single-phase,
200 V
A5A
X5052
45.0
1.0
01A
X5052
45.0
1.0
02A
X5053
20.0
2.0
04A
X5054
5.0
3.0
08A
X5056
2.0
5.0
Three-phase,
200 V
10A
X5061
2.0
4.8
15A
X5060
1.5
8.8
20A
30A
X5059
1.0
14.0
SIEPS80000025.book 21 ページ 2004年10月25日 月曜日 午前11時57分