9 Output Assemblies (Drive Consumes)
YASKAWA ELECTRIC
SIEP YEACOM 01A V1000 Option EtherNet/IP Technical Manual
29
MEMOBUS/Modbus Message Output (Vendor Specific YE Assy) - 100 (0x64)
Note:
This is a paired assembly (100/150).
Table 11 Function Code Decode Table
Note:
Refer to the MEMOBUS/Modbus Data Table in Appendix C of the V1000 Technical Manual for a list of monitor data using the
MEMOBUS/Modbus message area.
Output Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
100
0
Function Code
1
Register Number (High Byte)
2
Register Number (Low Byte)
3
Register Data (High Byte)
4
Register Data (Low Byte)
Name
Description
Function Code
MEMOBUS/Modbus Function Code.
Refer to Function Code Decode Table on page 29
.
Register Number
MEMOBUS/Modbus Register Number
Register Data
MEMOBUS/Modbus Register Data
Function Code
MEMOBUS/Modbus Function
0x00
No Operation
0x03
Read Register
0x10
Write Register