6 Procedure A
24
YASKAWA
TOEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Installation Manual
4.
Select one of the four different length ground wires packaged with the option.
Choose the proper ground wire by first removing the ground terminal screw from the
. Test fit the screw (size M3.5 to M6) into each of the four ground
drive-side ring lugs prior to installation. Ground wire selection varies by drive model.
Figure 10
Figure 10 Ground Wire Selection
5.
On IP20/Open-Chassis models, connect the drive side of the ground wire to the
drive ground terminal.
Figure 11
Figure 11 Ground Wire Connection on IP20/Open-Chassis
6.
Proceed to STEP
on page
to continue the option installation procedure for
IP20/Open-Chassis models.
To Option ground screw FE
Screw size: M3
To drive ground terminal
Screw size: M3.5 to M6
Ground terminal
Ground wire
Ground wire
Drive-side
ground terminal
ring lug (size varies):
M3.5 to M6
Ring lug for
Option ground FE
Size: M3