38
YASKAWA
SIEP C730600 88F MECHATROLINK-III Technical Manual
INV_CTL Response
Byte
Response
Description
24
Reference selected with SEL_
REF1
Reference selected with SEL_REF1 (Lower)
25
Reference selected with SEL_REF1 (Upper)
26
Not used (Set to 0.)
27
Not used (Set to 0.)
28
Reference selected with SEL_
REF2
Reference selected with SEL_REF2 (Lower)
29
Reference selected with SEL_REF2 (Upper)
30
Not used (Set to 0.)
31
Not used (Set to 0.)
■
INVCMD_CTRL
Vendor Specific
bit 1
bit 0
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
Not used
Reverse operation
Forward operation
Vendor Specific
bit 9
bit 8
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
Not used
External base block
reference
Clear the fault
history
External fault
(EF0)
Fault reset
Reserved (0)
Vendor Specific
bit 23
bit 22
bit 21
bit 20
bit 19
bit 18
bit 17
bit 16
Not used
1000-Series Drives, GA700, GA800, CR700, and CH700: Multi-Function Input Terminal 3 - 8
GA500: Multi-Function Input Terminal 3 - 7
bit 31
bit 30
bit 29
bit 28
bit 27
bit 26
bit 25
bit 24
Reserved (0)
Table 9.6 INVCMD_CTRL Bits
Bit
Name
Description
0
Forward operation
0: Stop
1: Forward operation
1
Reverse operation
0: Stop
1: Reverse operation
9
Fault Reset
1: Fault reset
10
External fault (EF0)
1: External fault input (EF0)
11
Clear fault history
1: Clear fault history
12
External base block reference
1: External base block reference ON
16
Multi-function input terminal 3
Multi-function input terminal S3
0: Multi-function input terminal S3 is OFF
1: Multi-function input terminal S3 is ON
17
Multi-function input terminal 4
Multi-function input terminal S4
0: Multi-function input terminal S4 is OFF
1: Multi-function input terminal S4 is ON
18
Multi-function input terminal 5
Multi-function input terminal S5
0: Multi-function input terminal S5 is OFF
1: Multi-function input terminal S5 is ON
19
Multi-function input terminal 6
Multi-function input terminal S6
0: Multi-function input terminal S6 is OFF
1: Multi-function input terminal S6 is ON