42
YASKAWA
SIEP C730600 88F MECHATROLINK-III Technical Manual
Vendor Specific
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
Not used
bit31
bit30
bit29
bit28
Vendor Specific
bit27
bit26
bit25
bit24
Reserved (0)
Not used
10
Sub-Command
Use sub-commands after selecting the 64-byte data transmission (
F6-21 = 0
).
◆
SUB_CTRL (Sub-Command Control Field)
Table 10.1 SUB_CTRL
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Reserved (0)
bit15
bit14
bit13
bit12
bit11
bit10
bit9
bit8
Reserved (0)
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
Reserved (0)
◆
SUB_STAT (Sub-Command Status)
Table 10.2 SUB_STAT
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Not used
Reserved (0)
SUBCMDRDY
Not used
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
Reserved (0)
SUBCMD_ALM
bit 23
bit 22
bit 21
bit 20
bit 19
bit 18
bit 17
bit 16
Reserved (0)
SEL_MON6
Status
SEL_MON5
Status
SEL_MON4
Status
SEL_MON3
Status
Command
Description
SUBCMDRDY
0: Sub-command reception disabled
1: Sub-command reception enabled
SUBCMD_ALM
Notifies the sub-command error state.
If a normal sub-command is received after the occurrence of a sub-command error, SUBCMD_ALM is automatically cleared.
SEL_MON3 Status
0: Disabled
1: SEL_MON3 enabled
SEL_MON4 Status
0: Disabled
1: SEL_MON4 enabled
SEL_MON5 Status
0: Disabled
1: SEL_MON5 enabled
SEL_MON6 Status
0: Disabled
1: SEL_MON6 enabled
Table 10.3 SUBCMD_ALM
Code (Hex.)
Description
-
00
Normal
Warning
01
Invalid data