6.2 List of Servo Parameters
6-18
Pn50A
2
Input Signal Selections
1
0000h to
FFF2h
–
1881h
Rotary
After
restart
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
P-OT (Forward Drive Prohibit) Signal Allocation
0
Enable forward drive when CN1-13 input signal is ON (closed).
1
Enable forward drive when CN1-7 input signal is ON (closed).
2
Enable forward drive when CN1-8 input signal is ON (closed).
3
Enable forward drive when CN1-9 input signal is ON (closed).
4
Enable forward drive when CN1-10 input signal is ON (closed).
5
Enable forward drive when CN1-11 input signal is ON (closed).
6
Enable forward drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit forward drive.
8
Set the signal to always enable forward drive.
9
Enable forward drive when CN1-13 input signal is OFF (open).
A
Enable forward drive when CN1-7 input signal is OFF (open).
B
Enable forward drive when CN1-8 input signal is OFF (open).
C
Enable forward drive when CN1-9 input signal is OFF (open).
D
Enable forward drive when CN1-10 input signal is OFF (open).
E
Enable forward drive when CN1-11 input signal is OFF (open).
F
Enable forward drive when CN1-12 input signal is OFF (open).