6.2 List of Servo Parameters
6-23
6
Parameter Li
s
t
s
Pn514
2
Output Signal Selec-
tions 4
0000h to
0666h
–
0000h
Rotary
After
restart
Setup
*1
Pn516
2
Input Signal Selections
7
0000h to
FFFFh
–
8888h
Rotary
After
restart
Setup
*1
Pn518
*3
–
Safety Module-Related
Parameters
–
–
–
Rotary
–
–
–
Pn51B
4
Motor-Load Position
Deviation Overflow
Detection Level
0 to
1,073,741,824
1 refer-
ence
unit
1000
Rotary
Immedi-
ately
Setup
*1
Pn51E
2
Position Deviation Over-
flow Warning Level
10 to 100
1%
100
Rotary
Immedi-
ately
Setup
*1
Pn520
4
Position Deviation Over-
flow Alarm Level
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
Rotary
Immedi-
ately
Setup
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
/PM (Preventative Maintenance Output) Signal Allocation
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-1 or CN1-2 output terminal.
2
Output the signal from the CN1-23 or CN1-24 output terminal.
3
Output the signal from the CN1-25 or CN1-26 output terminal.
4 to 6
Reserved setting (Do not use.)
n.X
Reserved parameter (Do not change.)
n.
X
FSTP (Forced Stop Input) Signal Allocation
0
Enable drive when CN1-13 input signal is ON (closed).
1
Enable drive when CN1-7 input signal is ON (closed).
2
Enable drive when CN1-8 input signal is ON (closed).
3
Enable drive when CN1-9 input signal is ON (closed).
4
Enable drive when CN1-10 input signal is ON (closed).
5
Enable drive when CN1-11 input signal is ON (closed).
6
Enable drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit drive (always force the motor to stop).
8
Set the signal to always enable drive (always disable forcing the motor to
stop).
9
Enable drive when CN1-13 input signal is OFF (open).
A
Enable drive when CN1-7 input signal is OFF (open).
B
Enable drive when CN1-8 input signal is OFF (open).
C
Enable drive when CN1-9 input signal is OFF (open).
D
Enable drive when CN1-10 input signal is OFF (open).
E
Enable drive when CN1-11 input signal is OFF (open).
F
Enable drive when CN1-12 input signal is OFF (open).
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)