3.2 Settings for Triggers at Preset Positions
3.2.1 Setting Table Details
3-6
*1.
The selected axis number, output terminals, and signal logic are enabled after the power supply is turned OFF
and ON again or after the Setup Device command (CONFIG) is sent from the host controller.
*2.
The passing direction is enabled immediately after it is changed.
Output Time
Set the output time of the preset position signal output.
•
High-Speed Output Settings
•
Normal Output Settings
Output Distance
Set the output width of the present position signal output as a distance.
1
Output Terminals and
Signal Logic
*1
(High-Speed Output
Settings)
0
Disable. (The signal is not output.)
1
Output the signal from the CN1-17 and CN1-18 output terminals.
2
Output the signal from the CN1-21 and CN1-22 output terminals.
3
Output the reverse signal from the CN1-17 and CN1-18 output
terminals.
4
Output the reverse signal from the CN1-21 and CN1-22 output
terminals.
5 to A
Disable. (The signal is not output.)
Output Terminals and
Signal Logic
*1
(Normal Output
Settings)
0
Disable. (The signal is not output.)
1
Output the signal from the CN1-1 and CN1-2 output terminals.
2
Output the signal from the CN1-23 and CN1-24 output terminals.
3
Output the signal from the CN1-25 and CN1-26 output terminals.
4
Disable. (The signal is not output.)
5
Disable. (The signal is not output.)
6
Output the reverse signal from the CN1-1 and CN1-2 output ter-
minals.
7
Output the reverse signal from the CN1-23 and CN1-24 output
terminals.
8
Output the reverse signal from the CN1-25 and CN1-26 output
terminals.
9
Disable. (The signal is not output.)
A
Disable. (The signal is not output.)
2
Passing Direction
*2
0
Output the signal at the preset position during forward movement.
1
Output the signal at the preset position during reverse movement.
2
Output the signal at the preset position during forward or reverse
movement.
3 to 7
Reserved (Do not use.)
Size
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
4
0 to 32,767,000
1
μ
s
0
Immediately
Setup
Size
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
4
0 to 65,535
1 ms
0
Immediately
Setup
Size
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
4
0 to 4,294,967,295
Reference
units
0
Immediately
Setup
Continued from previous page.
Digit
Name
Setting
Description