4.2 Setup Procedure
4.2.5 Servo Commands to Use
4
Rotational Coor
dinate
S
y
s
tem
4-9
External Input Constant-Speed Feeding and External Input
Positioning
If you enable the rotational coordinate system and execute external input constant-speed feed-
ing (EX_FEED) or external input positioning (EX_POSING), positioning is performed within the
range of the rotational coordinate system to external input positioning position P3 after latching
is performed for the external input positioning signal.
S
peed
P
3
S
VCMD_CTRL.CANCEL = 1
Feed
s
peed
P2 (Latched po
s
ition data)
Time
External input po
s
itioning
s
ignal
External po
s
itioning
final travel di
s
tance