4.2 Setup Procedure
4.2.6 Monitoring
4
Rotational Coor
dinate
S
y
s
tem
4-13
Monitoring with the Digital Operator
Display the monitor data in Monitor Mode to monitor values on the Digital Operator.
The monitor data, which is output within the range of the rotational coordinate system (Pn87A
to Pn87C), are listed below.
Refer to the following manual for information on monitor data that is not listed above.
Σ
-7-Series Digital Operator Operating Manual (Manual No.: SIEP S800001 33)
Un No.
Sign
Unit
Name
Description
Un045
Yes
1 reference unit
CPOS
Reference position
Un046
Yes
1 reference unit
APOS
Feedback position