9 Appendix
9.1.2 Parameters
9-12
Pn281
2
Reserved (Do not change.)
−
–
20
−
–
−
Pn304
2
JOG Speed
0 to 10000
1 min
-1
500
Immediately
Setup
6.3
Pn305
2
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immediately
Setup
*1
Pn306
2
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immediately
Setup
*1
Pn310
2
Vibration Detection Switch
0000 to 0002
−
0000
Immediately
Setup
−
Pn311
2
Vibration Detection
Sensibility
50 to 500
1%
100
Immediately
Tuning
6.13
Pn312
2
Vibration Detection Level
0 to 5000
1 min
-1
50
Immediately
Tuning
6.13
Pn324
2
Moment of Inertia Calculating Start Level
0 to 20000
1%
300
Immediately
Setup
5.2.1
Pn401
2
Torque Reference Filter Time Constant
0 to 65535
0.01 ms
100
Immediately
Tuning
5.7.3
Pn402
2
Forward Torque Limit
0 to 800
1%
800
Immediately
Setup
4.5.1
Pn403
2
Reverse Torque Limit
0 to 800
1%
800
Immediately
Setup
4.5.1
Pn404
2
Forward External Torque Limit
0 to 800
1%
100
Immediately
Setup
4.5.2
Pn405
2
Reverse External Torque Limit
0 to 800
1%
100
Immediately
Setup
4.5.2
Pn406
2
Emergency Stop Torque
0 to 800
1%
800
Immediately
Setup
4.3.2
Pn407
2
Speed Limit during Torque Control
0 to 10000
1 min
-1
10000
Immediately
Setup
4.7.8
∗1.
For details, refer to the
Σ
-V Series/DC Power Input
Σ
-V Series/
Σ
-V Series for Large-Capacity Models User’s Man-
ual MECHATROLINK-II Commands
(Manual No.: SIEP S800000 54).
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Vibration Detection Selection
Reference
Section
0
Does not detect vibration.
6.13
1
Outputs warning (A.911) when vibration is detected.
2
Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.