9.1 List of Parameters
9-21
9
Ap
pend
ix
Pn526
4
Excessive Position Error Alarm Level at
Servo ON
1 to
1073741823
1
reference
unit
5242880
Immediately
Setup
5.1.4
Pn528
2
Excessive Position Error Warning Level
at Servo ON
10 to 100
1%
100
Immediately
Setup
5.1.4
Pn529
2
Speed Limit Level at Servo ON
0 to 10000
1 min
-1
10000
Immediately
Setup
5.1.4
Pn52A
2
Reserved (Do not change.)
–
–
20
–
–
–
Pn52B
2
Overload Warning Level
1 to 100
1%
20
After restart
Setup
4.3.7
Pn52C
2
Derating of Base Current at Detecting
Overload of Motor
10 to 100
1%
100
After restart
Setup
4.3.7
Pn52D
2
Reserved (Do not change.)
–
–
50
–
–
–
Pn52F
2
Power ON Monitor Display
−
−
0FFF
−
−
–
Pn530
2
Program JOG Operation Related Switch
0000 to 0005
−
0000
Immediately
Setup
6.5
Pn531
4
Program JOG Movement
Distance
1 to
1073741824
1
reference
unit
32768
Immediately
Setup
6.5
Pn533
2
Program JOG Movement Speed
1 to 10000
1 min
-1
500
Immediately
Setup
6.5
Pn534
2
Program JOG Acceleration/Deceleration
Time
2 to 10000
1 ms
100
Immediately
Setup
6.5
Pn535
2
Program JOG Waiting Time
0 to 10000 1
ms
100
Immediately
Setup
6.5
Pn536
2
Number of Times of Program JOG Move-
ment
0 to 1000
1 time
1
Immediately
Setup
6.5
Pn550
2
Analog Monitor 1 Offset Voltage
-10000 to
10000
0.1 V
0
Immediately
Setup
5.1.3
Pn551
2
Analog Monitor 2 Offset Voltage
-10000 to
10000
0.1 V
0
Immediately
Setup
5.1.3
Pn552
2
Analog Monitor
Magnification (
×
1)
-10000 to
10000
×
0.01
100
Immediately
Setup
5.1.3
Pn553
2
Analog Monitor
Magnification (
×
2)
-10000 to
10000
×
0.01
100
Immediately
Setup
5.1.3
Pn560
2
Remained Vibration
Detection Width
1 to 3000
0.1%
400
Immediately
Setup
5.5.1
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Program JOG Operation Switch
0
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
1
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
2
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
3
(Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
(Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
4
(Waiting time Pn535
→
Forward movement Pn531
→
Waiting time Pn535
→
Reverse movement Pn531) × Number of movements Pn536
5
(Waiting time Pn535
→
Reverse movement Pn531
→
Waiting time Pn535
→
Forward movement Pn531) × Number of movements Pn536
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.